Event Monitor Cyber
EM-20261125-5IIR VulnerabilityHigh severity

Danfoss AK-SM 800A Series Improper Input Validation Vulnerability

CVE-2023-25915 · Danfoss AK-SM 800A Series

Share

12 hours from first report to confirmed exploitation.

Status
Confirmed

Since : CISA added it to Known Exploited Vulnerabilities.

First Signal
Nov 25 00:00 UTCC30 VulnCheck KEV
Page Born
Nov 25 12:00 UTCsecond source joined
Last Signal
Nov 25 12:00 UTC24 hours before snapshot
Sources
32 official · 1 research, news or crowd
Open For
21 hoursso far

Life Of This Page

  1. 1
    Born
    A second, independent source names it.
  2. 2
    Developing
    New signals join; severity can move.
  3. 3
    Confirmed · Now
    CISA KEV lists it, or exploitation in the wild is reported.
  4. 4
    Resolved
    Not yet
    Past the fix deadline and 14 days with no new signal.
  5. 5
    Archived
    Not yet
    30 days after resolved. Read only; the link keeps working. Reopens if it comes back.

The ID never changes, and earlier addresses keep working. A correction is logged, never overwritten. If two pages turn out to be one incident, the later one points to the earlier.

Vulnerability Lifecycle

  1. Disclosed: reached
    Nov 25 00:00 UTC
    C30 first to name it
  2. Scored: reached
    Nov 25 00:00 UTC
    No CVSS yet · EPSS 1.4%
  3. Exploited: reached
    Nov 25 12:00 UTC
    C1 CISA KEV, fix by Nov 28
  4. Advisories: reached
    Nov 25 12:00 UTC
    1 government and CERT sources
  5. Vendor Response: not yet
    Not yet
    None in sources yet
  6. Resolved: not yet
    Not yet
    When fixed: KEV deadline Nov 28, then 14 quiet days

Timeline

18:00Nov 2506:0012:0018:00BornC30 VulnCheck KEVC1 CISA Known Exploited VulnerabilitC2 CISA Cybersecurity Advisories

Point at a mark to read it. Squares are signals, colored by severity; every one is also listed under Signals.

Signals

  1. CISA Adds 10 Known Exploited Vulnerabilities to Catalog (opens source in a new tab) CISA has added 10 new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog , based on evidence of active exploitation. CVE-2023-25914 Danfoss AK-SM 800A Series Path Traversal Vulnerability… High severityGovernmentC2 CISA Cybersecurity Advisories
  2. CVE-2023-25915 added to KEV: Danfoss AK-SM 800A Series Improper Input Validation Vulnerability (opens source in a new tab) Danfoss AK-SM 800A Series contains an improper input validation vulnerability that could allow a remote attacker to run arbitrary commands on the affected system. High severityExploited ListC1 CISA Known Exploited Vulnerabilities
  3. CVE-2023-25915 known exploited (VulnCheck KEV): Danfoss AK-SM 800A Series Improper Input Validation Vulnerability (opens source in a new tab) Danfoss AK-SM 800A Series contains an improper input validation vulnerability that could allow a remote attacker to run arbitrary commands on the affected system. High severityResearch & NewsC30 VulnCheck KEV