Event Monitor Cyber
EM-20261124-LBEX OutageHigh severity

Lumen: Network Connectivity Drop

Nov 23, 2026 · Carrier · reported by IODA (Georgia Tech), RIPE Atlas (probes in carrier networks)

Share
Status
Resolved

Since : no provider status page involved; 6 hours with no new signal.

First Signal
Nov 23 23:35 UTCC111 IODA (Georgia Tech)
Page Born
Nov 24 16:06 UTCsecond source joined
Last Signal
Nov 24 16:06 UTC44 hours before snapshot
Sources
20 official · 2 research, news or crowd
Lasted
23 hoursfirst signal to resolved

Life Of This Page

  1. 1
    Born
    A second, independent provider or measurement sees it.
  2. 2
    Developing
    Reports and measurements join.
  3. 3
    Confirmed
    Skipped
    A provider status page acknowledges it.
  4. 4
    Resolved · Now
    Every provider marks it resolved and 6 hours pass quietly, or 24 hours pass with no new signal.
  5. 5
    Archived
    Not yet
    30 days after resolved. Read only; the link keeps working. Reopens if it comes back.

The ID never changes, and earlier addresses keep working. A correction is logged, never overwritten. If two pages turn out to be one incident, the later one points to the earlier.

Outage Lifecycle

  1. First Report: reached
    Nov 23 23:35 UTC
    C111 IODA (Georgia Tech)
  2. Corroborated: reached
    Nov 24 16:06 UTC
    2 independent sources
  3. Acknowledged: not yet
    Not yet
    No provider status page yet
  4. Network Check: reached
    Nov 23 23:35 UTC
    C111 IODA: network normal (lowest 98.7%)
  5. Restored: reached
    Nov 24 22:06 UTC
    No provider status page involved; 6 hours with no new signal

Timeline

18:00Nov 2406:0012:0018:00Nov 25BornResolvedC111 IODA (Georgia Tech)C115 RIPE Atlas (probes in carrier nCrowd posts

Point at a mark to read it. Squares are signals, colored by severity; every one is also listed under Signals.

Lumen Network During The Incident

0%50%100%Nov 22 22hNov 23 10hNov 23 22hNov 24 10h

Solid blue line: routes announced. Dashed amber line: networks answering pings. Both as a share of Lumen's normal, from C111 IODA, lowest reading in each 2 hours; the shaded band is the incident. The network itself stayed at normal (lowest 98.7%): the problem was in the service, not the network.

Signals

  1. Lumen AS3356: RIPE Atlas probes connected fell from 14 to 10 (opens source in a new tab) 8 probes now disconnected. High severityMeasurementC115 RIPE Atlas (probes in carrier networks)
  2. Connectivity drop: AS393789 (CENTURYLINK-CHIA) (CenturyLink Communications, LLC) (opens source in a new tab) 1 IODA alerts in 6 hours (1 critical), signals: bgp. Entity type: asn. Med severityMeasurementC111 IODA (Georgia Tech)
  3. Connectivity drop: AS393789 (CENTURYLINK-CHIA) (CenturyLink Communications, LLC) (opens source in a new tab) 2 IODA alerts in 6 hours (1 critical), signals: bgp. Entity type: asn. Med severityMeasurementC111 IODA (Georgia Tech)
  4. Connectivity drop: AS393789 (CENTURYLINK-CHIA) (CenturyLink Communications, LLC) (opens source in a new tab) 2 IODA alerts in 6 hours (1 critical), signals: bgp. Entity type: asn. Med severityMeasurementC111 IODA (Georgia Tech)

Crowd Posts At The Time

  1. Lumen: Some problems detected (crowd reports) (opens source in a new tab) 2 user reports in the last 2 hours against a baseline of 0. High severityCrowdT49 istheservicedown (carrier report curves)
  2. Lumen: Some problems detected (crowd reports) (opens source in a new tab) 4 user reports in the last 2 hours against a baseline of 0. High severityCrowdT49 istheservicedown (carrier report curves)
  3. Lumen: Some problems detected (crowd reports) (opens source in a new tab) 1 user reports in the last 2 hours against a baseline of 0. High severityCrowdT49 istheservicedown (carrier report curves)

Public posts naming Lumen within 6 hours of the incident. Shown for context; they do not change the status.